Use este identificador para citar ou linkar para este item: http://carpedien.ien.gov.br:8080/handle/ien/2250
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorSilviani, Maria Inês-
dc.contributor.authorAlmeida, Gevaldo Lisboa de-
dc.contributor.authorFurieri, Rosanne Cefaly Aranda Amado-
dc.date.accessioned2018-04-13T18:52:57Z-
dc.date.available2018-04-13T18:52:57Z-
dc.date.issued2004-11-
dc.identifier.urihttp://carpedien.ien.gov.br:8080/handle/ien/2250-
dc.languageengpt_BR
dc.publisherInstituto de Engenharia Nuclearpt_BR
dc.rightsopenAccesspt_BR
dc.subjectTomografiapt_BR
dc.subjectNeutrongrafiapt_BR
dc.subjectNêutrons térmicospt_BR
dc.subjectImagem em tempo realpt_BR
dc.titleThermal neutron computed tomography at the Argonauta Reactorpt_BR
dc.typereportpt_BR
dc.description.resumoSince 1985 the Argonauta Reactor at the Instituto de Engenharia Nuclear - IEN/CNEN has been used as a source of thermal neutrons to acquire transmission-generated radiographic images. From that time until the end of the last century, some Universities and Research Institutions have as well used the irradiation facilities of this reactor for that purpose and for technical and scientific training of personnel. Quite recently, a joint work program with the Laborat´orio de Instrumentac¸ ˜ao Nuclear - LIN/COPPE-UFRJ has been initiated addressing the research in the field of radiographic images using thermal neutrons, with special emphasis on Computer Aided Tomography. Within this frame, different tomographic systems - each one with their intrinsic features - have been developed aiming at their use in the industry field which requires the inspection of objects exhibiting different sizes and compositions. This work focuses the developed tomographs presenting their constraints and performances such as Spatial Resolution, Modulation Transfer Function and Density Resolution. The acquired images of some objects and test-bodies are as well presented for the sake of qualitative evaluation. They show a fair agreement with the performance of the tomographic system as expected from the measured quantitative parameters.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.initialsIENpt_BR
dc.creator.affiliationInstituto de Engenharia Nuclear-
Aparece nas coleções:Outras produções: Relatórios

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
RT-IEN-02-2004.pdf2,45 MBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.